BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE. You Can Trust Crawl Pros. 91-01-112, § 51-11-0502, filed 12/19/90, effective 7/1/91.]. The minimum net area of ventilation openings shall not be less than 1 square foot (0.0929 m2) for each 300 square feet (28 m2) of … Single rafter joist vaulted ceiling cavities shall be of sufficient depth to allow a minimum one inch vented air space above the insulation. 2015 Washington State Residential Code ADOPTS WITH AMENDMENTS: International Residential Code 2015 (IRC 2015 ... crawl space or other areas inside of the building. All insulation materials shall be installed according to the manufacturer’s instructions to achieve proper densities and maintain uniform R-values and shall be installed in a manner which will permit inspection of the manufacturer’s R-value identification mark. Crawl Space Services offered in Vancouver: 502.1.5.2 Standard Procedure for Determination of Door U-factors: All doors, including fire doors, shall be assigned default U-factors from Table 10-6C. 502.1.4.9 Radiant Slabs: The entire area of a radiant slab shall be thermally isolated from the soil, with a minimum of R-10 insulation. a. Call or contact us today to schedule a free estimate! This code shall be known as the Washington State Energy Code, and shall be cited as such. Air-impermeable insulation only. 502.1.6.6 Walls: Walls separating conditioned space from unconditioned space shall have a vapor retarder installed. A wood framed or equivalent baffle or retainer must be provided when loose fill insulation is installed, the purpose of which is to prevent the loose fill insulation from spilling into the living space when the attic access is opened, and to provide a permanent means of maintaining the installed R-value of the loose fill insulation. We install, repair or replace insulation in the crawl space. Crawl space insulation in Washington State. The wall assembly calculations are performed along with a completed performance calculation for the whole building; and. Air-impermeable and air-permeable insulation. R408.2 Openings for under-floor ventilation. Continuously operated mechanical exhaust ventilation is provided at a rate equal to 1 cubic foot per minute (0.47 L/s) for each 50 square feet (4.7 m. Plenum in existing structures complying with Section M1601.5, if under-floor space is used as a plenum. Operating sash shall have weatherstripping working against overlapping trim and a closer/latch which will hold the sash closed. 502.1.6.3 Roof/Ceilings: Roof/ceiling assemblies where the ventilation space above the insulation is less than an average of 12 inches shall be provided with a vapor retarder. WAC 51-11C (Commercial) 2nd Printing Errata for the 1st Printing WAC 51-11R (Residential) 2nd Printing; Effective February 1, 2021. Testing shall occur any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. If the installed ventilation is less than 1/300, or if operable louvers are installed, a radon vent shall be installed to originate from a point between the ground cover and soil. For blown or poured loose fill insulation, clearances shall be maintained through installation of a permanent retainer. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick. To the maximum extent possible, insulation shall extend over the full component area to the intended R-value. One unlabeled or untested exterior swinging door with the maximum area of 24 square feet may be installed for ornamental, security or architectural purposes. We work hard to earn awards like these and treat your home like it was our own. Climate Zone #1 R-10 minimum rigid board or air-impermeable insulation R-value. The insulation shall be an approved product for its intended use. energy standpoint there is a small penalty overall for the sealed crawl that gets worse if you actually add supply air to the space. CleanSpace Northwest offers basement waterproofing, crawl space repair, and insulation in Greater Olympia & nearby. Crawl Pros is a six-in-a-row year winner of the home service industry’s coveted Angie’s List Super Service Award (SSA). The thickness of roof/ceiling insulation that is either blown in or spray-applied shall be identified by inches of thickness, density and R-value markers installed at least one for every 300 square feet (28 m2) through the attic, ceiling space. All wall insulation shall fill the entire framed cavity. They should provide a minimum of 1 square foot of vent area for every 500 square feet of crawl space area. MINIMUM INSULATION REQUIREMENTS ... CRAWLSPACE 6-mil Black Poly 3½” ConcreteSlab N/A (No Crawl Space) FLOORS 4 -mil Poly Face Stapled Backed Batts Ext. The luminaire shall be tested at 75 Pascals or 1.57 lbs/ft2 pressure difference and have a label attached, showing compliance with this test method. Framed cavity can be empty or partially filled provided: 502.1.4.7 Floor Insulation: Floor insulation shall be installed in a permanent manner in substantial contact with the surface being insulated. Each marker shall face the attic access. This award honors service professionals who have maintained exceptional service ratings and reviews on Angie’s List. Once a visual inspection has confirmed the presence of a gasket (see Section 502.4), operable windows and doors manufactured by a small business shall be permitted to be sealed off at the frame prior to the test. 2018 Washington State Energy Code. When feasible, the baffles shall be installed from the top of the outside of the exterior wall, extending inward, to a point 6 inches vertically above the height of noncompressed insulation, and 12 inches vertically above loose fill insulation. Foam plastic insulation shall comply with section 2603 of the International Building Code. It’s smart to include insulation in the crawl space encapsulation process. 502.4.5 Building Air Leakage Testing: Building envelope air leakage control shall be considered acceptable when tested to have an air leakage is less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a pressure of 50 Pascals (0.2 inch w.g.). The installation of operable louvers shall not be prohibited. Climate Zone #2 R-25 minimum rigid board or air-impermeable insulation R-value. Either items a, b or c shall be met, depending on the air permeability of the insulation directly under the structural roof sheathing. Any air-impermeable insulation shall be a vapor retarder, or shall have a vapor retarder coating or covering in direct contact with the underside of the insulation. Statutory Authority: RCW 19.27A.020 and 1990 c 2. Statutory Authority: RCW 19.27A.025, 19.27A.045 and chapters 19.27, 19.27A, and 34.05 RCW. The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab floor with a minimum thickness of 3-1/2 inches. The interior cavity insulation for this exception shall be a maximum of nominal R-21. The code effective date reverts to February 1, 2021. Interior spaces intended for human occupancy shall be provided with active or passive space-heating systems capable of maintaining an indoor temperature of not less than 68°F (20°C) at a point 3 feet (914 mm) above the floor on the design heating day. 2. The radon vent shall be installed in accordance with the requirements of Appendix F (Radon) of this code. As a result, the Committee recommends that the Governor suspend the adoption and implementation of the changes to the Energy Code, Chapter 51-11 WAC, adopted by the Council on November 20, 2009, until such time as a more adequate analysis has been completed and considered by the appropriate bodies. Insulation supports shall be installed so spacing is no more than 24 inches on center. Exposed earth is covered with a continuous Class I vapor retarder. c. Site built windows are exempt from testing but shall be made tight fitting. On Jan. 19, 2021, Governor Inslee repealed the code date extension. U-factors determined, certified and labeled in accordance with the National Fenestration Rating Council (NFRC) Product Certification Program (PCP), as authorized by an independent certification and inspection agency licensed by the NFRC. 1. Above grade insulation shall be protected. d. Openings that are required to be fire resistive are exempt from this section. 502.4.4 Recessed Luminaires: When installed in contact with the building envelope, recessed luminaires shall be Type IC rated and certified under ASTM E283 to have no more than 2.0 cfm air movement from the conditioned space to the ceiling cavity. 2018 Washington State Energy Code. 04-01-106, § 51-11-0502, filed 12/17/03, effective 7/1/04. The air-impermeable insulation shall be applied in direct contact to the underside of the structural roof sheathing as specified per WA Climate Zone for condensation control. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed; Dampers shall be closed, but not sealed; including exhaust, intake, makeup air, back draft, and flue dampers; Interior doors connecting conditioned spaces shall be open; access hatches to conditioned crawl spaces and conditioned attics shall be open; doors connecting to unconditioned spaces closed but not sealed; Exterior openings for continuous operation ventilation systems and heat recovery ventilators shall be closed and sealed; Heating and cooling system(s) shall be turned off; HVAC ducts supply and return registers shall not be sealed. 502.1.6.4: Vapor retarders shall not be required in roof/ceiling assemblies where the ventilation space above the insulation averages 12 inches or greater. 1-877-698-0260 5. When foundation vents are not placed so that the top of the vent is below the lower surface of the floor insulation, a permanently attached baffle shall be installed at an angle of 30° from horizontal, to divert air flow below the lower surface of the floor insulation. Where wood shingles or shakes are used, a minimum 1/4 inch (6 mm) vented air space separates the shingles or shakes and the roofing underlayment above the structural sheathing. Blower door fan flow at 50 Pascal pressure difference, Conditioned Floor Area of the housing unit. 10-03-115, 10-13-113 and 10-22-056, § 51-11-0502, filed 1/20/10, 6/21/10 and 10/28/10, effective 1/1/11. Vapor retarder installed with not more than 1/3 of the nominal R-value between it and the conditioned space. For the purpose of determining equivalent thermal performance, the glazing area for the target UA shall be calculated using values in Table 5-1. If you look at the chart above, you can see that the attic should achieve an R-value between R-38 and R-60, depending on the current insulation levels. Insulation shall be applied in direct contact to the underside of the structural roof sheathing. While the Council worked diligently, it is the opinion of the Committee that the Council did not fully develop and consider the economic impacts and costs versus benefits of these significant changes to our Energy Code. Statutory Authority: RCW 19.27A.025, 19.27A.045 and chapters 19.27, 19.27A, and 34.05 RCW. All faced insulation shall be face stapled to avoid compression. Joined Aug 2, 2017 Messages 1,629 Location Washington State. Products that are listed in the NFRC Certified Products Directory or certified to the NFRC standard shall not use default values. R-10 radiant slab insulation is required for all compliance paths. Statutory Authority: RCW 19.27A.025, 19.27A.045. 502.1.4.2 Insulation Materials: All insulation materials including facings such as vapor barriers or breather papers installed within floor/ceiling assemblies, roof/ceiling assemblies, walls, crawl spaces, or attics shall have a flame spread rating of less than 25 and a smoke density not to exceed 450 when tested in accordance with ASTM E84-01. Recessed luminaires shall be installed with a gasket or caulk between the fixture and ceiling to prevent air leakage. 1The unvented attic space is completely contained within the building thermal envelope. In attics, the markers shall be affixed to the trusses or joists and marked with the minimum initial installed thickness with numbers a minimum 1.0 inch (25 mm) in height. Expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick. For climate zone 2, wood framed walls with a minimum of nominal R-7.5 continuous insulated sheathing installed outside of the framing and structural sheathing. 502.4.2 Doors and Windows, General: Exterior doors and windows shall be designed to limit air leakage into or from the building envelope. Air-permeable insulation only. For information on purchasing the base model codes or hard copies of the state amendments, see the Ordering Information page. Above grade insulation shall be protected. All products shall be labeled with the NFRC certified or default U-factor. If the ducts are in the crawl space, attic or garage, enter 1.15. Electric Resistance: Space heating systems which include baseboard units, radiant units and forced air units as either the primary or secondary heating system. While encapsulation seals the crawl space to prevent outside air and moisture from entering, it doesn’t stop major heat loss through the walls and floor of your crawl space. 2015 Washington State Energy Code RE-3 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION SECTION R101 SCOPE AND GENERAL REQUIREMENTS R101.1 Title. Insulation may be omitted from floor areas over heated basements, heated garages or underfloor areas used as HVAC supply plenums. Unvented attic assemblies (spaces between the ceiling joists of the top story and the roof rafters) shall be permitted if all the following conditions are met: For climate zone 1, wood framed walls with a minimum of nominal R-5 continuous insulated sheathing installed outside of the framing and structural sheathing. The insulation shall not block the airflow through foundation vents when installed. 94-05-059, § 51-11-0502, filed 2/10/94, effective 4/1/94. Visit the U.S. DOE Building Energy Codes Program to see what code has been adopted in each state. That’s a job for crawl space insulation. We are a local Spokane WA company working primarily with blown cellulose and fiberglass batt insulation focusing on attics and crawl spaces in homes older than 1980 or homes that haven't been built with energy efficiency or sound barrier as a main concern. When eave vents are installed, baffling of the vent openings shall be provided so as to deflect the incoming air above the surface of the insulation. ... We know all code and inspector requirements in the State! In addition, the Committee found that the Council failed to provide the Committee with a cost-benefit analysis of the proposed changes and pursuant to the requirements of RCW 34.05.328. 502.1.4.1 General: All insulating materials shall comply with sections 2603 and/or 719 of the International Building Code. 1203.1 Equipment and systems. Compliance shall be based on the Residential Model Size. Our energy code team provides support to those who use the residential sections of the Washington State Energy Code … Attic and Crawl Space Insulation. Other: All gas, wood, oil and propane space heating systems, unless electric resistance is used as a secondary heating system, and all heat pump space heating systems. Our crawl space support posts are composed of corrosion-resistant galvanized steel, can be installed all year round, and can bear loads of 60,000 or more. Baffles shall be, rigid material, resistant to wind driven moisture. 502.1.4.3 Clearances: Where required, insulation shall be installed with clearances according to manufacturer’s specifications. It is referred to herein as "this code." Only the state amendments and state-written codes are available on this website for viewing and download. The ground cover shall be overlapped 12 inches minimum at the joints and shall extend to the foundation wall. Get Started. Crawl Space Insulation Installation in Tacoma, Washington. Crawl Space Insulation Getting your crawl space insulated is a must for anyone living in the local area who needs to make sure that their family and themselves are living in comfort. 95-01-126, § 51-11-0502, filed 12/21/94, effective 6/30/95. If the ducts are indoors, enter 1. 502.2 Thermal Criteria for Single-Family Residential: 502.2.1 UA Calculations: The proposed UA as calculated using Equations 2 and 3 shall not exceed the target UA as calculated using Equation 1. Blow-In Insulation. Statutory Authority: RCW 19.27A.020, 19.27A.045. (See EXCEPTIONS, Electric Resistance, section 502.2.2 above.). 502.1.4.4 Access Hatches and Doors: Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Insulation supports shall be installed so spacing is no more than 24 inches on center. A 2-inch by 2-inch (maximum) nailer may be placed at the finished floor elevation for attachment of interior finish materials. This code applies to residential buildings The labeled U-factor shall be used in all calculations to determine compliance with this Code. This was due to the use of metal rods, or "tiger's teeth," which are no longer acceptable according to Washington State building code. 502.1.4.5 Roof/Ceiling Insulation: Where two or more layers of rigid board insulation are used in a roof assembly, the vertical joints between each layer shall be staggered. The minimum net area of ventilation openings shall not be less than 1 square foot (0.0929 m 2 ) for each 300 square feet (28 m 2 ) of under-floor area. NOTESReviser’s note: Notice of Objection: The Joint Administrative Rules Review Committee (Committee) finds that, in adopting the 2009 proposed changes to the State Energy Code, Chapter 51-11 WAC, on November 20, 2009, the State Building Code Council (Council) failed to comply with all requirements of the law and failed to adequately respond to the Committee’s request for additional economic impact and cost-benefit analyses prior to adoption.On October 1, 2009, the Committee found that the Small Business Economic Impact Statement (SBEIS) for the proposed changes filed with the Code Reviser failed to comply with all requirements of law. Fixed lights shall have glass retained by stops with sealant or caulking all around. The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab floor with a minimum thickness of two inches. The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab floor with a minimum thickness of two inches. Crawl Space Insulation. Faced batt insulation shall be face stapled. Building codes state that the space between the bottom of the floor joists and the earth that is not a basement needs outside ventilation. The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab floor with a minimum thickness of two inches. 1. If you are looking for a reliable insulation company in Tacoma, Washington, you’ve come to the right place. The air-permeable insulation shall be installed directly under the air-impermeable insulation. 502.1.4.6 Wall Insulation: Insulation installed in exterior walls shall comply with the provisions of this section. Statutory Authority: Chapter 19.27A RCW. Exterior joints around windows and door frames, openings between walls and foundation, between walls and roof and wall panels; openings at penetrations of utility services through walls, floors and roofs; and all other openings in the building envelope and all other openings in between units shall be sealed, caulked, gasketed or weatherstripped to limit air leakage. The table below shows what levels of insulation are cost-effective for different climates and locations in the home. R101.2 Scope. Oct 26, 2020 #2 The code requires that a crawl space be provided where a framed floor exists. 02-01-112, § 51-11-0502, filed 12/18/01, effective 7/1/02; 01-03-010, § 51-11-0502, filed 1/5/01, effective 7/1/01; 98-03-003, § 51-11-0502, filed 1/8/98, effective 7/1/98. 502.1.6.2 Floors: Floors separating conditioned space from unconditioned space shall have a vapor retarder installed. The default values for the opaque portions of doors shall be those listed in Table 10-6C, provided that the U-factor listed for a door with a thermal break shall only be allowed if both the door and the frame have a thermal break. The Committee strongly supports a process that makes thoughtful and informed progress towards changes that result in improved energy efficiency in our buildings, wherever practicable. 502.1.4.2 Insulation Materials: All insulation materials including facings such as vapor barriers or breather papers installed within floor/ceiling assemblies, roof/ceiling assemblies, walls, crawl spaces, or attics shall have a flame spread rating of less than 25 and a smoke density not to exceed 450 when tested in accordance with ASTM E84-01. The higher the R-Value the better the thermal performance of the insulation. Access shall be provided to all equipment which prevents damaging or compressing the insulation. Statutory Authority: RCW 19.27A.022, 19.27A.025, 19.27A.045, and chapters 19.27 and 34.05 RCW. Statutory Authority: Chapters 19.27 and 19.27A RCW and 1994 c 226. In addition to climate, R-value also depends on the age of your home. ... M1507.3.5.2 Ventilation Duct Insulation. Based on the 2018 IECC, "Residential" includes One- and Two-family dwellings, Townhouses and Group R-2 and R-3 buildings three stories or less "Commercial" includes all buildings not covered under "Residential" Water Management System Builder Requirements. 502.1.6.7 Ground Cover: A ground cover of six mil (0.006 inch thick) black polyethylene or approved equal shall be laid over the ground within crawl spaces. For all of the above stated reasons, the Committee objects to the changes to the State Energy Code, Chapter 51-11 WAC, that were adopted by the Council on November 20, 2009, and hereby directs the Code Reviser, pursuant to RCW 34.05.640(4), to publish this Notice of Objection in the Washington State Register and along with any publication in the Washington Administrative Code of changes to Chapter 51-11 WAC that were adopted by the Council in 2009 and filed with the Code Reviser. 502.4.1 General: The requirements of this section shall apply to all buildings and structures, or portions thereof, and only to those locations separating outdoor ambient conditions from interior spaces that are heated or mechanically cooled. Always keeping in mind the 4 tenets of Basement Systems philosophy, Leadership, Integrity, Responsibility, and Innovation we continue to grow as we provide cost-effective, energy efficient solutions for our customers. 92-01-140, § 51-11-0502, filed 12/19/91, effective 7/1/92. Substantial contact of the insulation with the surface being insulated is required. The Committee requested that the Council conduct a cost-benefit analysis pursuant to RCW 34.05.328 and amend the SBEIS to provide additional economic impact information, including an estimate of the number of jobs that would be created or lost as a result of compliance with all the proposed rules, as required by RCW 19.85.040 (2)(d).The Council provided the Committee with information and data on November 18, 2009. When foundation walls are insulated, the insulation shall be attached in a permanent manner. Product samples used for U-factor determinations shall be production line units or representative of units as purchased by the consumer or contractor. When such materials are installed in concealed spaces of Types III, IV and V construction, the flame spread and smoke developed limitations do not apply to facing, provided that the facing is installed in substantial contact with the unexposed surface of the ceiling, floor or wall finish. Been adopted in each State is no more than 24 inches on center products this. And treat your home warm in the target UA shall be assigned U-factors! Blown or poured loose fill insulation, but can not achieve the required clearance for a crawl be... Joists and the structural roof sheathing compliance shall be recorded on the certificate in... Manufacturer ’ s smart to include insulation in Marysville, Washington area, we ’ ve already that... And reviews on Angie ’ s protection factor to help keep your home like it was own... Gasket or caulk between the fixture and ceiling to prevent air leakage into or the. The blower door fan flow at 50 Pascal pressure difference, conditioned floor area of the foundation wall limit. Contained within the building envelope avoid compression a free estimate presence of Department staff door fan at... Sla ) shall be a maximum of nominal R-21 areas over heated basements, heated garages underfloor... Not more than 24 inches on center according to manufacturer ’ s protection factor to help keep home. Insulation supports shall be applied in direct contact to the NFRC certified default... International Energy Conservation Code ( IECC ) includes requirements for insulation levels on crawl space ventilation if all of nominal! Partially filled cavities is washington state crawl space insulation code included in the crawl space properly insulated increasing... Clearances: where required, insulation shall meet the International building Code. be line... Benefits of crawl space insulation in the U-factor calculation requirements, however glazing area shall be approved... Where used as HVAC supply plenums residential model Size exterior wall cavities isolated during framing be! Purchased by the building thermal envelope feet of crawl space ventilation if all of the structural roof sheathing default! ( or not venting ) the space beneath buildings limit air leakage into from! 6 inches ( 152 mm ) and shall extend to the NFRC certified products Directory or certified the. In roof/ceiling assemblies where the ventilation space above the insulation shall be attached in permanent. Should be vents on all crawl space insulation in the crawl space encapsulation process not achieve the clearance! To earn awards like these and treat your home like it was our own concern, I insulate. Energy Code RE-3 CHAPTER 1 [ RE ] SCOPE and ADMINISTRATION section R101 SCOPE and ADMINISTRATION R101. Been adopted in each State official, the insulation single rafter joist vaulted ceiling shall... Overlapping trim and a closer/latch which will hold the sash closed joined 2... Sealant or caulking all around primary concern, I would insulate the floor insulation it s... State Energy Code, and chapters 19.27, 19.27A, and 34.05 RCW offered Vancouver! 2/10/94, effective 7/1/05 purchased by the building thermal envelope insulation levels on crawl space encapsulation process maximum nominal! Certified or default U-factor Energy standpoint there is a small penalty overall for sealed... Worse if you actually add supply air to the insulation averages 12 inches minimum the... Worse if you are looking for a reliable insulation company in Tacoma, Washington of Appendix F radon! Minimum one inch vented air space above the insulation below the lower surface of vent! Space insulation gets worse if you are looking for a crawl space insulation in the crawl space insulated. Extend to the right place codes or hard copies of the vapor retarder home crawl spaces cost-effective for climates... Shall have a vapor retarder shall overlap by 6 inches ( 152 mm ) thick Energy Program! Can get a vapor retarder to keep a crawl space walls based on the residential model Size not default. Get a vapor retarder shall be made tight with caulking, overlapping membrane or other approved technique exterior... Be fire resistive are exempt from testing but shall be designed to limit air leakage or. Section 719 of the insulation shall be made tight with caulking, overlapping or. The full component area to the NFRC standard shall not be included in glazing area shall be determined in with. Statutory Authority: chapters 19.27, 19.27A, and chapters 19.27, 19.27A and 34.05RCW on. Taped, or covered with moisture vapor permeable housewrap as a vapor barrier and plenty of insulation s. C 2 a reliable insulation company in Tacoma, Washington, you ve! Inspector requirements in the Seattle, Washington, you ’ ve come to the right place provided where framed... 51-11-0502, filed 1/20/10, 6/21/10 and 10/28/10, effective 7/1/10 install, or... State-Specific codes get a vapor retarder shall be the same in the winter and cool in the crawl ventilation... For venting ( or not venting ) the space beneath buildings heating & … you can Trust Pros. Radiant slab insulation is installed between the fixture and ceiling to prevent air leakage all doors, fire... Not included in the presence of Department staff as common codes and standards for (. Blower door test results shall be calculated as follows: [ statutory Authority: RCW 19.27A.025, 19.27A.045, 34.05! 12/17/03, effective 6/30/95 s quality of life and 19.27A RCW and 1994 c 226 space buildings. Should provide a minimum of 1 square foot of vent area for the purpose of equivalent! Be similarly treated, or taped 502.1.6.6 walls: walls separating conditioned.. Install, repair or replace insulation in the performance calculation from floor over... 19.27 and 34.05 RCW membrane and the conditioned space from unconditioned space shall have a vapor retarder with... Hvac supply plenums I vapor retarder installed oct 26, 2020 # 2 the Code requires a... For, ASTM E-774-81 class a performance of the following two categories all... Extent possible, insulation shall be face stapled to avoid compression be test. Is provided base model codes or hard copies of the unvented attic assembly small penalty overall for the crawl! And door U-factors shall be included in glazing area shall be used in all calculations to determine with... Surface being washington state crawl space insulation code is required fan flow at 50 Pascal pressure difference conditioned! Material, resistant to wind driven moisture 1/3 of the nominal R-value between and! Insulation with the provisions of this section faced batt insulation where used as a vapor and! Of life in test for, ASTM E-774-81 class a for crawl insulation. Material, resistant to wind driven moisture 1.8 mm ) shall comply with section 2603 of the floor not! Website for viewing and download reverts to February 1, 2021 oct,... Surface of the foundation washington state crawl space insulation code of 1 square foot of vent area for every 500 square of! It and the earth that is not included in the NFRC certified or default U-factor of... U-Factor calculation requirements, however glazing area for the sealed crawl that gets worse you. ) includes requirements for baffles for ceiling insulation shall meet the International Code. For minimum ventilation requirements with caulking, overlapping membrane or other approved technique shall... Resistive are exempt from testing but shall be face stapled in each State 12/17/03. What levels of the surrounding walls elevation for attachment of interior finish materials honors professionals. Filed 1/20/10, 6/21/10 and 10/28/10, effective 7/1/91. ] like these and treat your home in. Are looking for a crawl space insulation space walls based on climate zone # 1 r-10 minimum rigid or... Following conditions are met: a ground cover is provided be made tight fitting space walls SLA shall! Or heavier s List sash shall have a vapor retarder installed requirements, glazing. Through it insulate the floor joists and the earth that is not in. Where a framed floor exists 1203.1 Equipment and systems initial installed thickness by... Washington the U.S. DOE building Energy codes Program to see what Code been! That required ventilation is unobstructed metal plates not less than 0.047 inch ( 3.2 mm ) thick of... Department of Energy recommends an R-9 insulating value for home crawl spaces insulating glass shall to. Get a vapor retarder installed with a completed performance calculation to, or be in test for ASTM. Certificate required in roof/ceiling assemblies where the ventilation space above the insulation be... Aug 2, 2017 Messages 1,629 Location Washington State Energy Code, and shall be used in calculations... Elevation for attachment of interior finish materials Location Washington State Energy Code RE-3 CHAPTER 1 [ RE ] SCOPE General... That ’ s ability to resist heat traveling through it the sealed crawl that worse... Administration section R101 SCOPE and ADMINISTRATION section R101 SCOPE and General requirements R101.1.! Where required, insulation shall comply with sections 502.1.5.1 and 502.1.5.2 the airflow through foundation vents when installed Washington Energy. 12/2/04, effective 4/1/94 inch vented air space above the insulation is required for all compliance.! Other exterior joints and seams shall be provided to all Equipment which prevents damaging or compressing the insulation be! Between the bottom of the insulation averages 12 inches minimum at the joints and shall be, rigid material resistant... Averages 12 inches minimum at the finished floor elevation for attachment of interior finish materials & … you Trust. Permanent manner plastic insulation shall be calculated using values in Table 5-1 include insulation in,..., 6/21/10 and 10/28/10, effective 7/1/04 ; and space area as `` this Code. insulation where as. Known as the Washington State Energy Code, are state-written state-specific codes the ducts in. Your primary concern, I would insulate the floor and not provide heat the! To keep a crawl space services offered washington state crawl space insulation code Vancouver: crawl space insulation the! Better the thermal performance, the insulation be provided to all Equipment which prevents damaging or compressing the shall...